Most components used by the LH-Jetronic 2.4 and EZ 116 K to control and regulate Volvo's B230FT are directly usable with a stand-alone engine-management system. Modern stand-alone ECUs benefit from upgrading the throttle position switch to a potentiometer-style throttle position sensor, swapping the narrow-band O2 sensor for a wide-band sensor (with controller) and adding manifold air pressure and inlet air temperature sensors.
This little collection of part numbers, pinouts and sensor values may help you setting up a stand-alone ECU or diagnose electrical issues.
Please consider this to be incomplete and potentially inaccurate, especially when working with other variants of the Volvo Redblock or older versions of LH-Jetronic.
Inductive speed sensor (variable reluctance/VR sensor). The flywheel has a 60-2 tooth pattern. Trigger is 90° before TDC (first tooth should be on 87° before TDC).
Part numbers:
| Pin | Description |
|---|---|
| 1 | VR + |
| 2 | VR - |
| 3 | Shield/GND |
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| EZK | 10 | R (in SB) | 0.34 mm² |
| EZK | 23 | BL (in SB) | 0.34 mm² |
| EZK | 11 | SB (in SB) | (shield, combined O.D.: ~4.5 mm) |
References:
Two NTC thermistors (R(25): ~2 kΩ; B(20/80): ~3510 K) are combined in one housing with two signal pins (for LH and EZK respectively) and GND through the thread. Thread size is M12x1.5.
Part numbers:
| Temperature | Resistance (between one pin and GND) |
|---|---|
| -10°C (14°F) | 8260-10560 Ω |
| +20°C (68°F) | 2280-2720 Ω |
| +80°C (176°F) | 290-364 Ω |
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| LH | 13 | GR-W | 0.75 mm² |
| EZK | 2 | R-SB | 0.75 mm² |
References:
Part numbers:
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| EZK | 12 | BN (in GN) | (shield, combined O.D.: ~4.0 mm) |
| EZK | 13 | GN (in GN) | 1.0 mm² |
References:
Potentiometer with linear characteristic curve. Used on Volvo 850 and others. Adapter for Redblocks commercially available.
Part numbers:
| Pin | Description |
|---|---|
| 1 | GND |
| 2 | IN (5V) |
| 3 | OUT |
References:
The Bosch LSU 4.9 wide-band O2 sensor with a suitable controller is currently the most common way to monitor air-fuel ratio.
Part numbers:
References:
NTC thermistor (R(25): ~2 kΩ; B(20/80): ~3531 K). Pins for signal and GND. Thread size is M12x1.5.
Part numbers:
| Temperature | Resistance |
|---|---|
| -10°C (14°F) | 15462 Ω |
| +20°C (68°F) | 2500 Ω |
| +80°C (176°F) | 323 Ω |
References:
Low resistance injectors. A resistor pack is used as standard. In simultaneous configuration with four injectors combined on one channel ~4 A are drawn.
Part numbers:
Flow rate at 3 bar: 300 cm³/min
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| LH | 18 | GR | 2.5 mm² |
References:
Fires the coil when the input signal goes from high (5 V) to low.
Part numbers:
| Pin | Description |
|---|---|
| 1 | Coil negative |
| 2 | GND (Kl. 31) |
| 3 | Input shield/GND |
| 4 | Coil positive |
| 5 | Input |
| 6 | NC |
| 7 | NC |
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| EZK | 16 | GR (in BK) | 1.0 mm² (shielded, O.D.: ~4.0 mm) |
References:
Relay E. Contains fuel pump relay and enables it.
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| LH | 21 | R | 0.75 mm² |
References:
Relay E.
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| LH | 20 | Y-SB | 0.75 mm² |
References:
Part numbers:
| Connector | Pin | Wire color | Wire gauge |
|---|---|---|---|
| LH | 33 | R-SB | 0.75 mm² |
References:
| Color | Volvo | IEC 60757 | DIN 47002 |
|---|---|---|---|
| black | SB | BK | sw |
| brown | BN | BN | br |
| red | R | RD | rt |
| orange | OR | OG | or |
| yellow | Y | YE | ge |
| green | GN | GN | gn |
| blue | BL | BU | bl |
| violet | VO | VT | vi |
| grey | GR | GY | gr |
| white | W | WH | ws |
| pink | P | PK | rs |